Product profile
The CY-LRSGD filter reactor applies to VAR compensation and harmonic suppression systems. When connected with the capacitor, the filter reactor can generate the min. or max. impedance using its physical property - LC resonance to absorb or block the harmonic voltage and current of corresponding frequency in the grid, thus eliminating the harmonics and maintaining the power factor of the system at the optimum value to significantly improve the power quality of the grid.
Use Conditions
•Ambient temperature: -25 - +40℃; relative temperature ≤ 90% RH
•Altitude: no greater than 2,000 m
•Free from intense vibration and impact, inflammable and explosive articles and conductive dust
•Good ambient ventilation. When installed in a cabinet, a ventilator is required
•A temperature resistance grade of over H (180 °C)
Technical Parameter
•Applicable for systems of 400 V, 660 V, 690 V, etc.
•Frequency points of tuning: 150 Hz, 250Hz, 350Hz, 550Hz and the like
•Rated insulation level 3kV/min
•For temperature rise limits at each part of the reactor, the one of winding is 80 K, and the iron core, 95 K
•The noise level of the reactor shall not exceed 45 dB
•The reactance difference between any two phases of a three-phase reactor shall not exceed 3%
•Operational in a long-term manner when the sum of power frequency plus harmonics is 1.35 times of the rated current
Application occasion
To filter high harmonics and compensate for the power factor of power supply systems with strong current harmonics.